CEFR/NA Marine Flexible Power Cable | Fire-Resistant, PCP Sheath, Unarmored (0.6/1kV)

Product Overview

The CEFR/NA is a fire-resistant, unarmored marine flexible power cable designed for critical circuits within protected environments where maintaining circuit integrity during a fire is paramount. Featuring Ethylene Propylene Rubber (EPR) insulation and a robust Polychloroprene (PCP) sheath, it provides a flexible, lightweight, and safe wiring solution for essential emergency power, lighting, and control systems on vessels and in industrial settings.


Technical Specifications

  • Rated Voltage (U₀/U): 0.6/1 kV

  • Maximum Continuous Conductor Temperature: 90°C

  • Conductor: Tinned or Plain Stranded, Annealed Copper Wire (Class 5/6 flexible) (IEC 60228)

  • Available Cross-Sections: 0.75 mm² to 300 mm²

  • Core Configurations: 1 to 37 Cores


Cable Construction & Materials

Item Code Material / Description
Series Code C Marine Power Cable
Conductor / Tinned/Plain Stranded, Annealed Copper Wire (Flexible Class 5/6)
Insulation E EPR insulated
Sheath F PCP
Sheath Color / Black or other Color
Flammability NA Fire Resistant

Key Performance Characteristics

  • Certified Fire Resistance (IEC 60331): The cable is engineered to maintain circuit integrity and continue operating for a specified period under direct flame exposure, which is critical for all emergency and life-safety circuits.

  • Durable PCP Sheath: The Polychloroprene (PCP, Neoprene) sheath provides strong resistance to oils, ozone, weathering, and abrasion, offering robust environmental protection.

  • High Flexibility & Lightweight: As an unarmored cable with flexible Class 5/6 conductors, it offers exceptional ease of handling, routing, and installation in conduits, cable trays, and control panels.

  • Flame Retardant: Complies with IEC 60332-1 and IEC 60332-3-22, helping to inhibit the spread of flame along the cable run.


Standards & Compliance

This cable is designed and tested in accordance with key international marine and fire safety standards:

  • IEC 60092-350, 353 (General construction and requirements)

  • IEC 60228 (Conductors)

  • IEC 60092-360 (Insulation and sheath materials)

  • IEC 60331 (Fire Resistance)

  • IEC 60332-1 & IEC 60332-3-22 (Flame retardancy tests)


Typical Applications

This cable is specified for critical circuits within protected spaces where fire survival capability is required:

  • Marine & Offshore: Essential emergency circuits such as emergency lighting, alarm and detection systems, and control wiring within accommodation areas and control rooms on ships and offshore structures.

  • Industrial: Safety-critical power and control wiring in public buildings, hospitals, and industrial control panels where fire-resistant cabling is mandated for protected internal routes.