LiYCY Cable , Screened Signal Transmission Cable , 250/250V – VDE

Instrumentation Cables

Product Overview

The LiYCY cable is designed for signal transmission between electronic devices, in computer systems, or process control units with increased electromagnetic compatibility (EMC) requirements. It features a Class 5 fine stranded bare copper conductor, PVC insulation, a tinned copper wire braid (TCWB) screen, and a PVC outer sheath.

The cable is manufactured to VDE 0482-332-1-2 and EN 60811-2-, with flame retardant performance according to IEC 60332-1.

Features & Benefits

  • Screened Construction: Tinned copper wire braid (TCWB) screen provides effective protection against electromagnetic interference.

  • Flexible Conductors: Class 5 fine stranded bare copper for ease of installation.

  • PVC Insulation and Sheath: Durable PVC compounds for reliable electrical and mechanical performance.

  • Flame Retardant: Complies with IEC 60332-1.

  • Voltage Rating: 250/250V.

  • Test Voltage: 1.2kV.

  • Temperature Range: Fixed: -30°C to +180°C; Installation: -5°C to +70°C.

  • Minimum Bending Radius: Fixed installation: 6 x overall diameter.

  • Standard Compliant: VDE 0482-332-1-2, EN 60811-2-.

Typical Applications

  • Signal transmission between electronic devices

  • Computer systems

  • Process control units with increased EMC requirements

Construction

  • Conductor: Class 5 Fine Stranded Bare Copper

  • Insulation: PVC (Polyvinyl chloride)

  • Screen: TCWB (Tinned Copper Wire Braid)

  • Outer Sheath: PVC (Polyvinyl chloride)

Technical Specifications

Electrical & Thermal Characteristics

Parameter Value
Voltage Rating Uo/U 250/250V
Voltage Test 1.2kV
Temperature Rating – Fixed -30°C to +180°C
Temperature Rating – Installation -5°C to +70°C
Minimum Bending Radius – Fixed Installation 6 x overall diameter
Flame Retardant IEC 60332-1

Parameter Table – 0.75 mm² Conductor Size

No. of Cores x Cross-Section (mm²) Approximate Net Weight of Cu (kg/km) Approximate Net Weight of Cables (kg/km) Maximum Conductor Resistance at 20°C (ohm/km)
2 x 0.75 25.98 38.5 26
3 x 0.75 32.85 45.6 26
4 x 0.75 41.37 55.6 26
5 x 0.75 49.35 65.1 26
7 x 0.75 64.96 82.7 26
8 x 0.75 74.16 94.2 26
10 x 0.75 91.35 114.6 26
12 x 0.75 106.17 130.4 26
18 x 0.75 153.48 182.8 26
25 x 0.75 207.72 243.5 26
30 x 0.75 244.37 282.6 26

Parameter Table – 1.0 mm² Conductor Size

No. of Cores x Cross-Section (mm²) Approximate Net Weight of Cu (kg/km) Approximate Net Weight of Cables (kg/km) Maximum Conductor Resistance at 20°C (ohm/km)
2 x 1.00 31.67 46.6 19.5
3 x 1.00 41.39 56.6 19.5
4 x 1.00 51.91 68.9 19.5
5 x 1.00 62.76 81.7 19.5
7 x 1.00 83.12 104.4 19.5
10 x 1.00 117.31 145.4 19.5
12 x 1.00 136.9 166.2 19.5
18 x 1.00 199.05 234.6 19.5
25 x 1.00 270.56 314 19.5

Parameter Table – 1.5 mm² Conductor Size

No. of Cores x Cross-Section (mm²) Approximate Net Weight of Cu (kg/km) Approximate Net Weight of Cables (kg/km) Maximum Conductor Resistance at 20°C (ohm/km)
2 x 1.5 42.16 60.4 13.3
3 x 1.5 55.88 74.5 13.3
4 x 1.5 71.49 92.3 13.3
5 x 1.5 86.5 109.6 13.3
6 x 1.5 101.92 127.6 13.3
7 x 1.5 115.53 141.6 13.3
8 x 1.5 131.75 161.4 13.3
10 x 1.5 163.84 198.4 13.3
12 x 1.5 191.62 227.6 13.3
14 x 1.5 220.6 258.9 13.3
16 x 1.5 249.79 290.8 13.3
19 x 1.5 294.69 338.5 13.3
24 x 1.5 394.72 448.7 13.3
27 x 1.5 437.24 492.7 13.3
37 x 1.5 583.86 648.9 13.3

Note: All values are nominal as provided in the source specification. Actual dimensions and weights may vary within standard manufacturing tolerances.

Standards & Compliance

  • VDE 0482-332-1-2

  • EN 60811-2-

  • Flame Retardant: IEC 60332-1

Ordering Information

To request a quote or place an order, please provide the following information:

  • Product Type: LiYCY Cable

  • Voltage Rating: 250/250V

  • Number of Cores and Cross-Section: e.g., 2 x 0.75 mm², 5 x 1.0 mm², 10 x 1.5 mm²

  • Conductor: Class 5 fine stranded bare copper

  • Insulation: PVC

  • Screen: Tinned copper wire braid (TCWB)

  • Outer Sheath: PVC

  • Quantity: Total length in meters