Product Overview
The LiYCY cable is designed for signal transmission between electronic devices, in computer systems, or process control units with increased electromagnetic compatibility (EMC) requirements. It features a Class 5 fine stranded bare copper conductor, PVC insulation, a tinned copper wire braid (TCWB) screen, and a PVC outer sheath.
The cable is manufactured to VDE 0482-332-1-2 and EN 60811-2-, with flame retardant performance according to IEC 60332-1.
Features & Benefits
-
Screened Construction: Tinned copper wire braid (TCWB) screen provides effective protection against electromagnetic interference.
-
Flexible Conductors: Class 5 fine stranded bare copper for ease of installation.
-
PVC Insulation and Sheath: Durable PVC compounds for reliable electrical and mechanical performance.
-
Flame Retardant: Complies with IEC 60332-1.
-
Voltage Rating: 250/250V.
-
Test Voltage: 1.2kV.
-
Temperature Range: Fixed: -30°C to +180°C; Installation: -5°C to +70°C.
-
Minimum Bending Radius: Fixed installation: 6 x overall diameter.
-
Standard Compliant: VDE 0482-332-1-2, EN 60811-2-.
Typical Applications
-
Signal transmission between electronic devices
-
Computer systems
-
Process control units with increased EMC requirements
Construction
-
Conductor: Class 5 Fine Stranded Bare Copper
-
Insulation: PVC (Polyvinyl chloride)
-
Screen: TCWB (Tinned Copper Wire Braid)
-
Outer Sheath: PVC (Polyvinyl chloride)
Technical Specifications
Electrical & Thermal Characteristics
| Parameter | Value |
|---|---|
| Voltage Rating Uo/U | 250/250V |
| Voltage Test | 1.2kV |
| Temperature Rating – Fixed | -30°C to +180°C |
| Temperature Rating – Installation | -5°C to +70°C |
| Minimum Bending Radius – Fixed Installation | 6 x overall diameter |
| Flame Retardant | IEC 60332-1 |
Parameter Table – 0.75 mm² Conductor Size
| No. of Cores x Cross-Section (mm²) | Approximate Net Weight of Cu (kg/km) | Approximate Net Weight of Cables (kg/km) | Maximum Conductor Resistance at 20°C (ohm/km) |
|---|---|---|---|
| 2 x 0.75 | 25.98 | 38.5 | 26 |
| 3 x 0.75 | 32.85 | 45.6 | 26 |
| 4 x 0.75 | 41.37 | 55.6 | 26 |
| 5 x 0.75 | 49.35 | 65.1 | 26 |
| 7 x 0.75 | 64.96 | 82.7 | 26 |
| 8 x 0.75 | 74.16 | 94.2 | 26 |
| 10 x 0.75 | 91.35 | 114.6 | 26 |
| 12 x 0.75 | 106.17 | 130.4 | 26 |
| 18 x 0.75 | 153.48 | 182.8 | 26 |
| 25 x 0.75 | 207.72 | 243.5 | 26 |
| 30 x 0.75 | 244.37 | 282.6 | 26 |
Parameter Table – 1.0 mm² Conductor Size
| No. of Cores x Cross-Section (mm²) | Approximate Net Weight of Cu (kg/km) | Approximate Net Weight of Cables (kg/km) | Maximum Conductor Resistance at 20°C (ohm/km) |
|---|---|---|---|
| 2 x 1.00 | 31.67 | 46.6 | 19.5 |
| 3 x 1.00 | 41.39 | 56.6 | 19.5 |
| 4 x 1.00 | 51.91 | 68.9 | 19.5 |
| 5 x 1.00 | 62.76 | 81.7 | 19.5 |
| 7 x 1.00 | 83.12 | 104.4 | 19.5 |
| 10 x 1.00 | 117.31 | 145.4 | 19.5 |
| 12 x 1.00 | 136.9 | 166.2 | 19.5 |
| 18 x 1.00 | 199.05 | 234.6 | 19.5 |
| 25 x 1.00 | 270.56 | 314 | 19.5 |
Parameter Table – 1.5 mm² Conductor Size
| No. of Cores x Cross-Section (mm²) | Approximate Net Weight of Cu (kg/km) | Approximate Net Weight of Cables (kg/km) | Maximum Conductor Resistance at 20°C (ohm/km) |
|---|---|---|---|
| 2 x 1.5 | 42.16 | 60.4 | 13.3 |
| 3 x 1.5 | 55.88 | 74.5 | 13.3 |
| 4 x 1.5 | 71.49 | 92.3 | 13.3 |
| 5 x 1.5 | 86.5 | 109.6 | 13.3 |
| 6 x 1.5 | 101.92 | 127.6 | 13.3 |
| 7 x 1.5 | 115.53 | 141.6 | 13.3 |
| 8 x 1.5 | 131.75 | 161.4 | 13.3 |
| 10 x 1.5 | 163.84 | 198.4 | 13.3 |
| 12 x 1.5 | 191.62 | 227.6 | 13.3 |
| 14 x 1.5 | 220.6 | 258.9 | 13.3 |
| 16 x 1.5 | 249.79 | 290.8 | 13.3 |
| 19 x 1.5 | 294.69 | 338.5 | 13.3 |
| 24 x 1.5 | 394.72 | 448.7 | 13.3 |
| 27 x 1.5 | 437.24 | 492.7 | 13.3 |
| 37 x 1.5 | 583.86 | 648.9 | 13.3 |
Note: All values are nominal as provided in the source specification. Actual dimensions and weights may vary within standard manufacturing tolerances.
Standards & Compliance
-
VDE 0482-332-1-2
-
EN 60811-2-
-
Flame Retardant: IEC 60332-1
Ordering Information
To request a quote or place an order, please provide the following information:
-
Product Type: LiYCY Cable
-
Voltage Rating: 250/250V
-
Number of Cores and Cross-Section: e.g., 2 x 0.75 mm², 5 x 1.0 mm², 10 x 1.5 mm²
-
Conductor: Class 5 fine stranded bare copper
-
Insulation: PVC
-
Screen: Tinned copper wire braid (TCWB)
-
Outer Sheath: PVC
-
Quantity: Total length in meters