MV-90/MV-105 URD Cable | 5-46 kV Underground Power Distribution | TR-XLPE Insulated

Product Overview

The MV-90/MV-105 URD Cable is a medium-voltage underground residential distribution cable designed for reliable power transmission in harsh environments. Certified to UL 1072ICEA S-94-649, and AEIC CS8, it features tree-retardant XLPE insulation and sunlight-resistant LLDPE sheathing, making it ideal for direct burial, duct banks, and industrial applications.


Key Features

  • High Voltage Rating: 5 kV to 46 kV for utility and industrial distribution.

  • Temperature Range-40°C to 105°C (130°C emergency overload; 250°C short-circuit).

  • Conductor Options: Solid/stranded aluminum (1350 alloy) or copper.

  • Environmental Resistance: UV, moisture, and chemical-resistant LLDPE jacket.

  • Certifications: UL 1072, ICEA S-94-649, AEIC CS8, CSA.


Technical Specifications

Parameter Details
Voltage Rating 5 kV – 46 kV
Conductor Aluminum (1350) or Copper (Class B Stranded)
Insulation Tree-Retardant XLPE (TR-XLPE)
Neutral Concentric Bare Copper
Jacket UV-Resistant LLDPE (Black)
Temperature Range Operating: -40°C to 105°C
Bending Radius Installation: 20x Diameter
Fixed: 15x Diameter

Applications

Utility & Infrastructure

  • Underground Distribution: Residential/commercial power grids.

  • Renewable Energy: Solar/wind farm collector systems.

  • Industrial Zones: Substations, chemical plants, and mining operations.

Commercial & Municipal

  • Duct Banks: Urban underground power networks.

  • Emergency Systems: Backup power circuits for hospitals/data centers.


Installation Guidelines

Approved Uses

  • Direct burial, conduits, trays, and ducts.

  • Wet/dry locations with sunlight exposure.

Prohibited Uses

  • ❌ Above-ground exposed runs without mechanical protection.

  • ❌ Temperatures exceeding 105°C (normal operation).

Key Notes

  • Neutral Configuration: Helically applied copper neutral for grounding.

  • Moisture Block: Optional conductor moisture barrier for wet environments.


Performance Advantages

  • Treeing Resistance: TR-XLPE prevents dielectric breakdown.

  • Durability: LLDPE jacket withstands soil stresses and rodent attacks.

  • Safety: Semi-conductive screens ensure even voltage distribution.

  • Flexibility: Cold bend tested to -40°C for winter installations.


FAQs

Q: Can MV-90 cables handle short-circuit conditions?
A: Yes. They withstand 250°C for short-circuit durations (per AEIC CS8).

Q: What’s the difference between MV-90 and MV-105?
A: MV-105 has a higher emergency overload rating (105°C vs. 90°C).

Q: Is this cable suitable for coastal areas?
A: Yes. The LLDPE jacket resists saltwater corrosion.


Ordering Options

  • Conductor: Aluminum or Copper.

  • Voltage: 5 kV, 15 kV, 25 kV, 35 kV, 46 kV.

  • Neutral: Bare copper concentric or optional configurations.

Custom lengths and bulk pricing for utilities!

58
35
64
Product Description 15kV Single Core 2 AWG Aluminium Conductor XLPE Insulation URD Cable (For South America) Key Features Voltage Rating: 15kV Underground Primary Distribution Conductor: 2 AWG Solid/Stranded Aluminium (ASTM B230/B232 Compliant) Insulation: TR-XLPE (Thermoset Cross-Linked Polyethylene) Shielding: Extruded Semiconducting Layer + Concentric Neutral (16×#14 AWG Bare Copper) Jacket: UV-Resistant LLDPE with Safety Markings Standards: AEIC CS8, ICEA S-94-649, UL-1072 Applications Underground power distribution (direct burial or conduit)...