Product Overview
The MV-90/MV-105 URD Cable is a medium-voltage underground residential distribution cable designed for reliable power transmission in harsh environments. Certified to UL 1072, ICEA S-94-649, and AEIC CS8, it features tree-retardant XLPE insulation and sunlight-resistant LLDPE sheathing, making it ideal for direct burial, duct banks, and industrial applications.
Key Features
-
High Voltage Rating: 5 kV to 46 kV for utility and industrial distribution.
-
Temperature Range: -40°C to 105°C (130°C emergency overload; 250°C short-circuit).
-
Conductor Options: Solid/stranded aluminum (1350 alloy) or copper.
-
Environmental Resistance: UV, moisture, and chemical-resistant LLDPE jacket.
-
Certifications: UL 1072, ICEA S-94-649, AEIC CS8, CSA.
Technical Specifications
Parameter | Details |
---|---|
Voltage Rating | 5 kV – 46 kV |
Conductor | Aluminum (1350) or Copper (Class B Stranded) |
Insulation | Tree-Retardant XLPE (TR-XLPE) |
Neutral | Concentric Bare Copper |
Jacket | UV-Resistant LLDPE (Black) |
Temperature Range | Operating: -40°C to 105°C |
Bending Radius | Installation: 20x Diameter Fixed: 15x Diameter |
Applications
Utility & Infrastructure
-
Underground Distribution: Residential/commercial power grids.
-
Renewable Energy: Solar/wind farm collector systems.
-
Industrial Zones: Substations, chemical plants, and mining operations.
Commercial & Municipal
-
Duct Banks: Urban underground power networks.
-
Emergency Systems: Backup power circuits for hospitals/data centers.
Installation Guidelines
Approved Uses
-
Direct burial, conduits, trays, and ducts.
-
Wet/dry locations with sunlight exposure.
Prohibited Uses
-
❌ Above-ground exposed runs without mechanical protection.
-
❌ Temperatures exceeding 105°C (normal operation).
Key Notes
-
Neutral Configuration: Helically applied copper neutral for grounding.
-
Moisture Block: Optional conductor moisture barrier for wet environments.
Performance Advantages
-
Treeing Resistance: TR-XLPE prevents dielectric breakdown.
-
Durability: LLDPE jacket withstands soil stresses and rodent attacks.
-
Safety: Semi-conductive screens ensure even voltage distribution.
-
Flexibility: Cold bend tested to -40°C for winter installations.
FAQs
Q: Can MV-90 cables handle short-circuit conditions?
A: Yes. They withstand 250°C for short-circuit durations (per AEIC CS8).
Q: What’s the difference between MV-90 and MV-105?
A: MV-105 has a higher emergency overload rating (105°C vs. 90°C).
Q: Is this cable suitable for coastal areas?
A: Yes. The LLDPE jacket resists saltwater corrosion.
Ordering Options
-
Conductor: Aluminum or Copper.
-
Voltage: 5 kV, 15 kV, 25 kV, 35 kV, 46 kV.
-
Neutral: Bare copper concentric or optional configurations.
Custom lengths and bulk pricing for utilities!