Product Overview
Battery Cable is intended for interconnection between batteries and starter or ground in vehicles. It is manufactured using stranded bare copper with PVC, rubber, TPR, or cross-link insulation to ensure reliable performance in engine compartments and other demanding environments.
Technical Data:
-
Temperature range:
-
During installation: +5°C up to +70°C
-
Fixed installed: -30°C up to +70°C
-
Short circuit (max. 5 s): up to 160°C
-
Ambient temperature at storage: up to 40°C
-
-
Minimum inner bending radius: 4D
Specifications
| Property | Details |
|---|---|
| Working Temperature | 70°C |
| Application | Battery to starter / ground interconnection |
Construction
Battery cable is manufactured using stranded bare copper with PVC, rubber, TPR, or cross-link insulation. Available in black or red rubber (SGR) – normally black, and PVC (SGT) in both colors.
Cable types:
-
SGT – Starter or Ground General Purpose Thermoplastic (PVC insulation)
-
SGR – Starter or Ground General Purpose Rubber
-
SGX – Starter Ground General Purpose Cross-Linked
Conductor: Bare copper according to ASTM
Insulation: PVC / Rubber / Cross-linked (as per type)
Possible insulation colors: As per customer request
Technical Parameters – Datasheet
| Size AWG | No. of Strands | Insulation Thickness (mm) | Insulation Thickness (inches) | Nominal Overall Diameter (mm) | Nominal Overall Diameter (inches) | Net Weight (kg/km) | Net Weight (lbs/mft) |
|---|---|---|---|---|---|---|---|
| 4 | 7 | 0 | 0 | 9.4 | 0.37 | 246.5 | 165.66 |
| 2 | 19 | 1.56 | 0.061 | 11.68 | 0.46 | 391.15 | 262.87 |
| 1 | 19 | 1.51 | 0.059 | 12.57 | 0.495 | 471.78 | 317.05 |
| 1/0 | 19 | 2.06 | 0.081 | 13.97 | 0.55 | 612.63 | 411.72 |
| 2/0 | 19 | 2.16 | 0.085 | 15.11 | 0.595 | 722.32 | 485.43 |
| 3/0 | 19 | 1.97 | 0.077 | 17.78 | 0.70 | 988.70 | 664.45 |
| 4/0 | 19 | 1.98 | 0.078 | 19.30 | 0.76 | 1271.27 | 854.35 |