Product Overview
CJ85 Armored Marine Power and Control Cable is engineered for demanding marine environments, providing reliable power distribution and control system connectivity. Rated at 0.6/1kV with 90°C operational capability, this cable combines XLPE insulation with thermosetting polyolefin sheath (SHF2) and metal braided armor for maximum protection in fixed installations.
Key Features
-
Rated Voltage: 0.6/1kV (U₀/U)
-
Temperature Rating: 90°C continuous operation
-
Conductor Options:
-
Class 2 (1.0-10mm²) for standard applications
-
Class 5 flexible (16-240mm²) for enhanced flexibility
-
-
Insulation: XLPE for superior thermal stability
-
Armor: Metal braided for mechanical protection
-
Sheath: Thermosetting Polyolefin (SHF2) - enhanced flame retardancy
-
Standards: Full compliance with IEC 60092 series
Applications
-
Power distribution systems on ships and vessels
-
Offshore petrol platforms and drilling installations
-
Marine building electrical systems
-
Lighting and control circuits
-
Fixed installations in ship areas including open decks
-
Mobile applications with flexible conductor options
Cable Construction
Detailed Construction
-
Conductor:
-
Stranded copper wire 1.0mm² to 10mm² (Class 2)
-
Stranded copper wire 16mm² to 240mm² (Class 5 Flexible)
-
Annealed stranded copper wire available on request
-
-
Insulation: XLPE (Cross-linked Polyethylene)
-
Bedding: Separate tape for core protection
-
Armor: Metal braided for mechanical strength
-
Sheath: Thermosetting Polyolefin (SHF2)
Technical Specifications
Service Conditions
-
Rated Voltage: U₀/U 0.6/1kV
-
Maximum Operating Temperature: 90°C
-
Installation Type: Fixed laying for armored versions
-
Flexible Options: Available with Class 5 conductors
Conductor Specifications
| Conductor Size | Conductor Class | Application Type |
|---|---|---|
| 1.0 - 10 mm² | Class 2 | Standard fixed installations |
| 16 - 240 mm² | Class 5 (Flexible) | Mobile applications |
Bending Radius Requirements
| Cable Structure | Cable Outer Diameter | Minimum Bending Radius |
|---|---|---|
| Metal Braided Armored | All sizes | 6 × D |
| Non-Armored | D ≤ 25 mm | 4 × D |
| Non-Armored | D > 25 mm | 6 × D |
Note: D = Cable outer diameter
Compliance & Standards
-
IEC 60092-350: Electrical installations in ships
-
IEC 60092-351: Insulating materials specification
-
IEC 60092-354: Cables with extruded solid insulation
-
IEC 60092-359: Sheathing materials requirements
-
Flame Retardant: SHF2 standard compliance
Quality Assurance
-
Manufactured under strict quality control standards
-
Comprehensive electrical and mechanical testing
-
Suitable for harsh marine environments
-
Documentation and certification provided
-
Reliable performance in fixed and mobile applications