TIBAS SIBAS Medium Voltage Marine Power Cable | IEC 60092 | 3.6/6kV to 26/35kV

Product Overview

TIBAS SIBAS Medium Voltage Marine Power Cables are engineered for reliable power distribution in demanding marine environments. Designed to meet international standards including IEC 60092, these cables ensure superior performance and safety for various vessel types.


Key Features

  • Voltage Rating: 3.6/6kV to 26/35kV

  • Temperature Rating: 90°C long-term operating temperature

  • Construction: Multi-layer screened design with EPR insulation

  • Armor Options: Galvanized steel wire or bronze wire braid

  • Standards Compliance: IEC 60092-350, -351, -354, -359

  • Flame Performance: IEC 60332-1 & -3 (Category A) certified


Applications

  • Cargo ships and container vessels

  • Passenger ships and cruise liners

  • Special-purpose vessels and offshore platforms

  • Marine power distribution systems


Cable Construction

  1. Conductor: Tinned annealed copper wire

  2. Conductor Screen: Semi-conducting tape + compound

  3. Insulation: EPR (Ethylene Propylene Rubber)

  4. Insulation Screen: Semi-conducting compound + tape

  5. Metallic Screen: Annealed copper tape

  6. Inner Covering: High modulus PVC

  7. Armor: Galvanized steel wire braid or bronze wire braid

  8. Sheath: Enhanced PVC for superior protection


Technical Specifications

Electrical Characteristics

  • Rated Voltage:
    3.6/6(7.2)kV, 6/10(12)kV, 8.7/15(17.5)kV,
    12/20(24)kV, 18/30(36)kV, 26/35kV

  • Test Voltage: AC 3.5kV/5 minutes withstand test

  • Operating Temperature: 90°C maximum continuous

Bending Radius Requirements

Cable Structure Cable Outer Diameter Minimum Bending Radius
Metal Braided Armored All sizes 6 × D
Non-Armored D ≤ 25 mm 4 × D
Non-Armored D > 25 mm 6 × D

Note: D = Cable outer diameter


Certifications & Standards

  • IEC 60092-350: Electrical installations in ships - General construction and test methods

  • IEC 60092-351: Insulating materials for shipboard power cables

  • IEC 60092-354: Power cables with extruded solid insulation

  • IEC 60092-359: Shipboard power cables with special fire performance

  • IEC 60332-1: Flame test for single vertical insulated wire/cable

  • IEC 60332-3: Flame spread testing for bunched cables


Quality Assurance

  • Manufactured under strict quality control standards

  • Regular testing for electrical and mechanical properties

  • Compliance with international marine safety requirements

  • Documentation and certification provided with each shipment