UL 854 SE/SEU/SER 2/0-4/0 AWG Aluminum Service Entrance Cable | XLPE Insulated, PVC Jacket | 90°C Wet/Dry Rating

Product Overview:

UL 854 Aluminum Service Entrance Cable

Type SE/SEU/SER aluminum service entrance cable provides reliable 600V power distribution from junction boxes to meter bases and distribution panels. Featuring AA-8030 alloy conductors, XLPE insulation, and sunlight-resistant PVC jacketing, this UL 854-compliant solution excels in wet/dry environments up to 90°C. Available in 2/0 AWG and 4/0 AWG configurations.


Key Applications

  • Service Entrance Runs: Meter base to distribution panel connections

  • Power Transmission: Junction box to meter base installations

  • Wet/Dry Locations: Indoor/outdoor environments including direct exposure

  • Residential/Commercial: NEC-compliant service entrance applications


Standards & Certifications

  • Conductors: ASTM B-800 & B-801

  • Insulation: UL 44 (XHHW-2 Rating)

  • Cable Standard: UL 854 (SER/SEU)

  • Environmental: RoHS Compliant (Heavy Metal-Free)

  • Voltage Rating: 600V


Construction & Material Specifications

Component Specification
Conductor AA-8030 Aluminum Alloy (8000 Series)
Insulation XLPE (Cross-Linked Polyethylene) - 90°C rated, abrasion/moisture/heat resistant
Flame Resistance Meets FT2 combustion requirements
Assembly Fibrage tape wrap over conductor core
Jacket UV-resistant PVC - Sunlight stable (720h tested), moisture/flame retardant
Temperature 90°C dry/wet locations

Conductor Identification:

  • 3-Conductor: Black, Black w/ Red Stripe

  • 4-Conductor: Black, Black w/ White Stripe, Black w/ Red Stripe

  • 5-Conductor: Black, Black w/ White Stripe, Black w/ Red Stripe, Black w/ Blue Stripe


Technical Advantages

  1. Alloy Conductors: AA-8030 aluminum offers superior creep resistance and conductivity

  2. XLPE Insulation: Maintains flexibility at -40°C to 90°C with excellent dielectric strength

  3. UV-Stable Jacket: Withstands prolonged sunlight exposure (720h tested)

  4. Wet Location Rated: Water-resistant construction for outdoor/damp installations

  5. Flame Performance: FT2-rated flame retardancy reduces fire propagation risk


Engineering Selection Guide

Parameter 2/0 AWG 4/0 AWG
Conductor Type AA-8030 Alloy AA-8030 Alloy
Voltage Rating 600V 600V
Temp. Rating 90°C (Wet/Dry) 90°C (Wet/Dry)
Insulation XLPE (UL 44) XLPE (UL 44)
Jacket UV-Resistant PVC UV-Resistant PVC
Applications Service Entrances High-Current Feeds

Note: Always verify ampacity using NEC Table 310.15(B)(16) and derate for ambient conditions


Compliance & Installation Notes

  • UL 854 Compliance: Suitable for above-ground service entrance applications

  • NEC Classification: Type SE cable per Article 338

  • Bending Radius: Minimum 7x cable diameter

  • Grounding: Separate equipment grounding conductor required per NEC 250.118

  • Conduit Use: Not required for exposed runs but recommended for physical protection