Product Overview
The CKEPF80/NC is a Fire Resistant (IEC 60331), single-sheathed marine control cable designed for essential circuits where maintaining operational integrity during fire is critical. It combines a Mica/EPR insulation system for fire survival with tinned copper braid armor for flexibility and EMI shielding, all housed in a single layer of Halogen-Free, Low Smoke (LSHF) sheath. This configuration is ideal for installations where space is a consideration and electromagnetic compatibility is important, fully complying with IEC 60092 standards.
Key Features & Benefits
-
Certified Fire Resistance: Meets IEC 60331 requirements, ensuring critical circuits for emergency lighting, alarms, and control systems remain functional under fire conditions.
-
Superior Safety & Environmental Profile: Halogen-Free (IEC 60754) and Low Smoke (IEC 61034) properties reduce hazardous emissions and improve visibility, safeguarding personnel and equipment.
-
Flexible Armor with EMI Shielding: The tinned copper wire braid armor provides excellent mechanical protection, good flexibility for easier installation, and effective protection against electromagnetic interference.
-
Compact & Durable Design: The single LSHF sheath over armor offers a streamlined profile for efficient cable routing while maintaining resistance to oils and chemicals.
Technical Specifications
-
Rated Voltage: 150/250V
-
Maximum Continuous Conductor Temperature: 90°C
-
Available Conductor Cross-Sections: 0.5 mm², 0.75 mm², 1.0 mm², 1.5 mm², 2.5 mm²
-
Core Configuration: 1 to 37 Cores.
Construction Details

| Item | Code | Material / Description |
|---|---|---|
| Series Code | CK | Marine & Offshore Control Cable |
| Conductor | / | Tinned / Plain Stranded, Annealed Copper Wire |
| Insulation | E | Mica Glass Tape + EPR Insulation |
| Inner Sheath | PF | Thermoplastic Polyolefin (SHF1) |
| Armor | 8 | Tinned / Plain Copper Wire Braided |
| Outer Sheath | 0 | Without Outer Sheath (Armor serves as final layer) |
| Flammability | NC | Halogen Free Low Smoke Fire Resistant |
Standards & Compliance
This cable is manufactured in full compliance with the following international standards:
-
General Design: IEC 60092-350, IEC 60092-376
-
Conductor: IEC 60228
-
Insulation & Sheath: IEC 60092-360
-
Fire Resistant: IEC 60331
-
Flame Retardant: IEC 60332-1, IEC 60332-3-22
-
Halogen Free: IEC 60754
-
Low Smoke Emission: IEC 61034
Applications
This cable is engineered for vital fixed circuits in environments requiring fire integrity and EMI protection:
-
Marine & Offshore: Critical power, lighting, and control systems on ships, oil platforms, and offshore structures, particularly in control rooms, panels, and enclosed trays.
-
Industrial Facilities: Essential safety and control circuits in power generation, chemical plants, and mining operations, especially where sensitive instrumentation is present.