SHD-GC MSHA Portable Power Cable | 8kV/15kV Mining & Heavy-Duty Cable

Product Overview

The SHD-GC MSHA Portable Power Cable is engineered for extreme-duty applications in mining and heavy industries. Certified to ICEA S-75-381 and CSA No. 96, it combines ethylene propylene rubber (EPR) insulation with a flame-retardant CPE jacket, ensuring reliability in harsh, mobile environments like draglines, shovels, and drills.


Key Features

  • High Voltage Rating: 8kV or 15kV for mobile mining equipment.

  • Temperature Range-40°C to 90°C (continuous operation).

  • Conductor: Annealed tinned copper (6 AWG–500 kcmil).

  • Safety Features: Integrated ground check conductor for fault detection.

  • Environmental Resistance: Oil, ozone, UV, and abrasion-resistant.


Technical Specifications

Parameter Details
Voltage Rating 8kV, 15kV
Conductor Tinned Copper (ASTM B172 Rope-Lay Stranded)
Insulation Ethylene Propylene Rubber (EPR)
Shielding Copper/Textile Braid + Semi-Conductive Layer
Jacket Flame-Retardant CPE (Chlorinated Polyethylene)
Temperature Range Operating: -40°C to 90°C
Certifications ICEA S-75-381, CSA No. 96, MSHA-Compliant

Applications

Mining & Heavy Industry

  • Draglines & Shovels: Power supply for excavation equipment.

  • Drills & Loaders: High-flexibility wiring for mobile machinery.

  • Underground Mining: Flame-resistant circuits in hazardous zones.

Utility & Construction

  • Dredges & Cranes: Wet/dry location power distribution.

  • Temporary Power: Generators and portable systems on remote sites.


Installation Guidelines

Approved Uses

  • Mobile equipment requiring frequent flexing.

  • Wet, oily, or abrasive environments.

  • MSHA-compliant mining operations.

Prohibited Uses

  • ❌ Permanent fixed installations.

  • ❌ Temperatures exceeding 90°C.

Key Notes

  • Bending Radius: Follow ICEA guidelines to avoid shield damage.

  • Ground Check: Yellow polypropylene-insulated conductor for safety monitoring.


Performance Advantages

  • Flexibility: Rope-lay stranding withstands repeated bending.

  • Safety: Flame-retardant jacket and ground check system prevent hazards.

  • Durability: CPE jacket resists oil, chemicals, and mechanical stress.

  • Compliance: Meets MSHA standards for underground mining safety.


FAQs

Q: Can SHD-GC cables handle extreme cold?
A: Yes. Rated for -40°C, they remain flexible in freezing conditions.

Q: What is the purpose of the ground check conductor?
A: It monitors circuit integrity, triggering shutdowns if a fault is detected.

Q: Are these cables suitable for coal mining?
A: Yes. MSHA compliance ensures safety in explosive atmospheres.


Ordering Options

  • Voltage: 8kV or 15kV.

  • Conductor Size: 6 AWG to 500 kcmil.

  • Configuration: 3-5 conductors + ground check.