Product Overview
The SHD-GC MSHA Portable Power Cable is engineered for extreme-duty applications in mining and heavy industries. Certified to ICEA S-75-381 and CSA No. 96, it combines ethylene propylene rubber (EPR) insulation with a flame-retardant CPE jacket, ensuring reliability in harsh, mobile environments like draglines, shovels, and drills.
Key Features
-
High Voltage Rating: 8kV or 15kV for mobile mining equipment.
-
Temperature Range: -40°C to 90°C (continuous operation).
-
Conductor: Annealed tinned copper (6 AWG–500 kcmil).
-
Safety Features: Integrated ground check conductor for fault detection.
-
Environmental Resistance: Oil, ozone, UV, and abrasion-resistant.
Technical Specifications
Parameter | Details |
---|---|
Voltage Rating | 8kV, 15kV |
Conductor | Tinned Copper (ASTM B172 Rope-Lay Stranded) |
Insulation | Ethylene Propylene Rubber (EPR) |
Shielding | Copper/Textile Braid + Semi-Conductive Layer |
Jacket | Flame-Retardant CPE (Chlorinated Polyethylene) |
Temperature Range | Operating: -40°C to 90°C |
Certifications | ICEA S-75-381, CSA No. 96, MSHA-Compliant |
Applications
Mining & Heavy Industry
-
Draglines & Shovels: Power supply for excavation equipment.
-
Drills & Loaders: High-flexibility wiring for mobile machinery.
-
Underground Mining: Flame-resistant circuits in hazardous zones.
Utility & Construction
-
Dredges & Cranes: Wet/dry location power distribution.
-
Temporary Power: Generators and portable systems on remote sites.
Installation Guidelines
Approved Uses
-
Mobile equipment requiring frequent flexing.
-
Wet, oily, or abrasive environments.
-
MSHA-compliant mining operations.
Prohibited Uses
-
❌ Permanent fixed installations.
-
❌ Temperatures exceeding 90°C.
Key Notes
-
Bending Radius: Follow ICEA guidelines to avoid shield damage.
-
Ground Check: Yellow polypropylene-insulated conductor for safety monitoring.
Performance Advantages
-
Flexibility: Rope-lay stranding withstands repeated bending.
-
Safety: Flame-retardant jacket and ground check system prevent hazards.
-
Durability: CPE jacket resists oil, chemicals, and mechanical stress.
-
Compliance: Meets MSHA standards for underground mining safety.
FAQs
Q: Can SHD-GC cables handle extreme cold?
A: Yes. Rated for -40°C, they remain flexible in freezing conditions.
Q: What is the purpose of the ground check conductor?
A: It monitors circuit integrity, triggering shutdowns if a fault is detected.
Q: Are these cables suitable for coal mining?
A: Yes. MSHA compliance ensures safety in explosive atmospheres.
Ordering Options
-
Voltage: 8kV or 15kV.
-
Conductor Size: 6 AWG to 500 kcmil.
-
Configuration: 3-5 conductors + ground check.
Custom lengths and bulk pricing for mining operators!