1. International Standards
- IEC Standards (International Electrotechnical Commission Standards)
- IEC 60227: PVC Insulated Cables.
- IEC 60245: Rubber Insulated Cables.
- IEC 60502: Power Cables with rated voltages from 1 kV to 30 kV.
- IEC 60754: Test for Gases Evolved During Combustion.
- IEC 61034: Smoke Density Test.
2. American Standards
- UL Standards (Underwriters Laboratories Standards)
- UL 44: Rubber Insulated Cables.
- UL 83: Thermoplastic Insulated Cables, such as THHN, THWN-2.
- UL 854: Service Entrance Cables (SE).
- UL 1277: Power-Limited Circuit Cables.
- UL 1666: Vertical Flame Test.
- NEC Standards (National Electrical Code)
- NEC Article 310: Installation Requirements for Power Cables.
- NEC Article 725: Installation Requirements for Control Cables.
3. European Standards
- EN Standards (European Standards)
- EN 50525: Low Voltage Cables.
- EN 50264: Cables for Railway Vehicles.
- EN 50382: High-Temperature Cables.
- EN 60332: Flame Retardant Test.
- BS Standards (British Standards)
- BS 5467: Rubber Insulated Cables.
- BS 6724: Flame Retardant Cables.
- BS 7870: Low Voltage Power Cables.
4. Australian/New Zealand Standards
- AS/NZS Standards
- AS/NZS 5000: Electric Cables.
- AS/NZS 1125: Cable Insulation and Sheath Materials.
- AS/NZS 3808: Flame Retardant Test.
5. Japanese Standards
- JIS Standards (Japanese Industrial Standards)
- JIS C 3306: Rubber Insulated Cables.
- JIS C 3401: PVC Insulated Cables.
- JIS C 3605: Power Cables.
6. Common Cable Models
- THHN/THWN-2:
- UL standard cables in the U.S., suitable for building wiring and power distribution.
- Conductor: Copper or aluminum.
- Insulation: Thermoplastic material (PVC).
- Rated Voltage: 600V.
- XHHW/XHHW-2:
- UL standard cables in the U.S., suitable for medium and low-voltage power systems.
- Conductor: Copper or aluminum.
- Insulation: Cross-linked polyethylene (XLPE).
- Rated Voltage: 600V to 35 kV.
- NYM-J:
- European standard cables, suitable for internal building wiring.
- Conductor: Copper.
- Insulation: Polyvinyl chloride (PVC).
- Rated Voltage: 300/500V.
- H07RN-F:
- European standard cables, suitable for mobile equipment and harsh environments.
- Conductor: Copper.
- Insulation: Rubber.
- Rated Voltage: 450/750V.
- ACSR:
- Aluminum Conductor Steel Reinforced cables, suitable for overhead power transmission.
- Conductor: Aluminum-clad steel core.
- Insulation: None (bare wire).
- MICC:
- Mineral Insulated Copper Clad cables, suitable for fire protection systems and high-temperature environments.
- Conductor: Copper.
- Insulation: Magnesium oxide.
- Rated Voltage: 600V to 1000V.
7. Special Cable Models
- Fire-Resistant Cables: Compliant with IEC 60331 standards.
- Flame Retardant Cables: Compliant with IEC 60332 standards.
- Submarine Cables: Suitable for underwater power or communication transmission.
- Solar Cables: Suitable for solar power generation systems.
8. How to Choose Standards and Models
- By Application Field: Such as construction, power, communication, and industry.
- By Voltage Level: Such as low voltage, medium voltage, and high voltage.
- By Regional Requirements: Such as UL standards in North America and EN standards in Europe.
- By Performance Requirements: Such as fire resistance, flame retardancy, and high-temperature resistance.