- SOOW Portable Power Cable Specifications-12AWG
Part Number No. of Conductors Nominal Insulation Thickness Nominal Overall Diameter Approx. Cable Weight lbs./kft Ampacity** 30°C
Ambientinches mm inches mm Copper 12AWG ASTM B174 Class K stranding (65 strands of 30AWG) 12‐02SOOW 2 0.045 1.14 0.58 14.6 201 25 12‐03SOOW 3 0.045 1.14 0.60 15.3 235 25 12‐04SOOW 4 0.045 1.14 0.65 16.5 291 20 12‐05SOOW 5 0.045 1.14 0.71 18.1 330 16 12‐06SOOW 6 0.045 1.14 0.74 18.8 360 16 12‐07SOOW 7 0.045 1.14 0.77 19.6 415 14 12‐08SOOW 8 0.045 1.14 0.83 21.0 470 14 12‐09SOOW 9 0.045 1.14 0.90 22.9 515 14 12‐10SOOW 10 0.045 1.14 1.00 25.4 580 14 12‐12SOOW 12 0.045 1.14 1.01 25.7 650 10 12‐14SOOW 14 0.045 1.14 1.08 27.4 740 10 12‐16SOOW 16 0.045 1.14 1.14 28.8 835 10 12‐18SOOW 18 0.045 1.14 1.15 30.0 910 10 12‐20SOOW 20 0.045 1.14 1.17 30.5 990 10 12‐24SOOW 24 0.045 1.14 1.40 35.6 1240 9 12‐26SOOW 26 0.045 1.14 1.40 35.6 1270 9 12‐27SOOW 27 0.045 1.14 1.49 37.7 1310 9 12‐28SOOW 28 0.045 1.14 1.50 38.1 1345 9 12‐30SOOW 30 0.045 1.14 1.50 38.1 1415 9 12‐36SOOW 36 0.045 1.14 1.65 42.0 1670 8 12‐40SOOW 40 0.045 1.14 1.69 42.9 1830 8 12‐44SOOW 44 0.045 1.14 1.89 47.9 2000 7 12‐50SOOW 50 0.045 1.14 1.97 50.1 2300 7 10AWG
Part Number No. of Conductors Nominal Insulation Thickness Nominal Overall Diameter Approx.
Cable Weight lbs./kftAmpacity** 30°C
Ambientinches mm inches mm Copper 10AWG ASTM B174 Class K stranding (104 strands of 30AWG) 10‐02SOOW 2 0.045 1.14 0.63 15.9 245 30 10‐03SOOW 3 0.045 1.14 0.66 16.8 307 30 10‐04SOOW 4 0.045 1.14 0.71 18.0 360 25 10‐05SOOW 5 0.045 1.14 0.77 19.6 465 20 10‐06SOOW 6 0.045 1.14 0.88 22.2 500 20 10‐08SOOW 8 0.045 1.14 0.94 23.9 625 17.5 10‐10SOOW 10 0.045 1.14 1.03 26.1 765 17.5 10‐12SOOW 12 0.045 1.14 1.14 29.0 865 12.5 10‐16SOOW 16 0.045 1.14 1.23 31.3 1150 12.5 10‐20SOOW 20 0.045 1.14 1.26 32.0 1445 12.5 - 14AWG
Part Number No. of Conductors Nominal Insulation Thickness Nominal Overall Diameter Approx. Cable Weight lbs./kft Ampacity** 30°C
Ambientinches mm inches mm Copper 14AWG ASTM B174 Class K stranding (41 strands of 30AWG) 14‐02SOOW 2 0.045 1.14 0.50 12.7 151 18 14‐03SOOW 3 0.045 1.14 0.53 13.5 176 18 14‐04SOOW 4 0.045 1.14 0.57 14.5 210 15 14‐05SOOW 5 0.045 1.14 0.65 16.5 275 12 14‐06SOOW 6 0.045 1.14 0.71 18.0 315 12 14‐07SOOW 7 0.045 1.14 0.71 18.0 345 10.5 14‐08SOOW 8 0.045 1.14 0.76 19.3 385 10.5 14‐09SOOW 9 0.045 1.14 0.83 21.1 410 10.5 14‐10SOOW 10 0.045 1.14 0.83 21.1 430 10.5 14‐12SOOW 12 0.045 1.14 0.87 22.1 485 7.5 14‐14SOOW 14 0.045 1.14 1.00 25.4 590 7.5 14‐16SOOW 16 0.045 1.14 1.03 26.2 665 7.5 14‐18SOOW 18 0.045 1.14 1.10 28.0 710 7.5 14‐20SOOW 20 0.045 1.14 1.16 29.4 780 7.5 14‐24SOOW 24 0.045 1.14 1.26 32.0 985 6.7 14‐28SOOW 28 0.045 1.14 1.33 33.8 1080 6.7 14‐30SOOW 30 0.045 1.14 1.34 34.1 1130 6.7 14‐37SOOW 37 0.045 1.14 1.48 37.6 1330 6 - 16AWG
Part Number No. of Conductors Nominal Insulation Thickness Nominal Overall Diameter Approx. Cable Weight lbs./kft Ampacity** 30°C
Ambientinches mm inches mm Copper 16AWG ASTM B174 Class K stranding (26 strands of 30AWG) 16‐02SOOW 2 0.030 0.76 0.37 9.4 78 13 16‐03SOOW 3 0.030 0.76 0.39 9.9 105 13 16‐04SOOW 4 0.030 0.76 0.43 10.8 120 10 16‐05SOOW 5 0.030 0.76 0.50 12.6 160 8 16‐06SOOW 6 0.030 0.76 0.52 13.2 175 8 16‐07SOOW 7 0.030 0.76 0.55 14.0 195 8 16‐08SOOW 8 0.030 0.76 0.58 14.6 220 7 16‐09SOOW 9 0.030 0.76 0.62 15.8 250 7 16‐10SOOW 10 0.030 0.76 0.65 16.5 280 7 16‐12SOOW 12 0.030 0.76 0.69 17.5 325 5 16‐14SOOW 14 0.030 0.76 0.72 18.1 355 5 16‐16SOOW 16 0.030 0.76 0.74 18.8 380 5 16‐20SOOW 20 0.030 0.76 0.81 20.6 480 5 16‐24SOOW 24 0.030 0.76 0.93 23.5 550 4.5 16‐30SOOW 30 0.030 0.76 1.05 26.7 715 4.5 16‐37SOOW 37 0.030 0.76 1.19 30.1 810 4 16‐40SOOW 40 0.030 0.76 1.24 31.5 850 4 16‐44SOOW 44 0.030 0.76 1.28 32.5 941 3.5 - 18AWG
Part Number No. of Conductors Nominal Insulation Thickness Nominal Overall Diameter Approx. Cable Weight lbs./kft Ampacity** 30°C
Ambientinches mm inches mm Copper 18AWG ASTM B174 Class K stranding (16 strands of 30AWG) 18‐02SOOW 2 0.030 0.76 0.35 8.8 75 10 18‐03SOOW 3 0.030 0.76 0.37 9.3 87 10 18‐04SOOW 4 0.030 0.76 0.39 9.9 102 7 18‐05SOOW 5 0.030 0.76 0.47 11.8 130 5.6 18‐06SOOW 6 0.030 0.76 0.50 12.6 150 5.6 18‐07SOOW 7 0.030 0.76 0.50 12.7 160 5.6 18‐08SOOW 8 0.030 0.76 0.53 13.5 170 4.9 18‐10SOOW 10 0.030 0.76 0.61 15.4 215 4.9 18‐12SOOW 12 0.030 0.76 0.61 15.4 245 3.5 18‐14SOOW 14 0.030 0.76 0.66 16.8 265 3.5 18‐16SOOW 16 0.030 0.76 0.71 17.9 310 3.5 18‐20SOOW 20 0.030 0.76 0.80 20.2 375 3.5 18‐24SOOW 24 0.030 0.76 0.90 22.9 450 3.2 18‐30SOOW 30 0.030 0.76 0.93 23.5 520 3.2 18‐36SOOW 36 0.030 0.76 1.05 26.7 600 2.8 - 8-2AWG
Part Number Size AWG No. of Conductors Conductor Strand Nominal Insulation Thickness Nominal Overall Diameter Current Amps
**Weight lbs./M inches mm inches mm SOOW‐8/3 8 3 133/29 0.060 1.52 0.720 21.72 40 491 SOOW‐8/4 8 4 133/29 0.060 1.52 0.780 24.64 35 640 SOOW‐8/5 8 5 133/29 0.060 1.52 0.860 27.30 28 690 SOOW‐6/3 6 3 133/27 0.060 1.52 0.800 24.89 55 695 SOOW‐6/4 6 4 133/27 0.060 1.52 0.890 27.69 45 850 SOOW‐6/5 6 5 133/27 0.060 1.52 0.945 31.12 36 930 SOOW‐4/3 4 3 133/25 0.060 1.52 0.940 28.96 70 950 SOOW‐4/4 4 4 133/25 0.060 1.52 1.010 32.00 60 1100 SOOW‐4/5 4 5 133/25 0.060 1.52 1.135 36.07 48 1160 SOOW‐2/3 2 3 133/23 0.060 1.52 1.090 33.73 80 1310 SOOW‐2/4 2 4 133/23 0.060 1.52 1.170 37.08 80 1590 SOOW‐2/5 2 5 133/23 0.060 1.52 1.435 40.89 65 1890